For this reason homeowners may want to contact a certified hvac technician or contractor to determine the optimal size of ductwork throughout the home or business environment that also measures up to code standards.
Standard hvac duct length.
A comprehensive duct layout indicating sizes design airflows pressure class and routing of the duct system.
Installing the duct incorrectly will affect the heating capacity of the system as much as improper sizing.
Install the appropriate duct size connections.
Sizing ducts for a heating system is a complex task.
And that my friend is the definition of effective length.
The types of fittings to be used based on the designer s calculations of fitting losses i e square versus 45 entry taps conical versus straight taps etc.
Information required for duct construction 1.
1 psi equals 27 7 inches of water gauge.
Duct system is pressurized by three pressures.
Ordinary heating ventilating and air conditioning duct systems read air pressures at 0 4 psi or less often much less.
Rectangular single wall duct ductwork fittings.
Run the correct size from the furnace and be sure they are installed correctly.
It involves the heat output of the unit measured in british thermal units the air flow from its blower the number of vents and their location and the length of ducts needed to reach those vents.
All ductwork comes standard with stiffening beads.
Maximum size of duct or pipe through steel joists k series joists and maximum size of ducts and pipes.
Rectangular duct and fittings are one part of our complete line of hvac products.
Smc tdc slip drive and raw sheet metal connectors inc.
Do that for all the ducts and branches on the table.
Equivalent diameter rectangular and circular hvac ducts equivalent diameter for rectangular and circular ducts air flows between 100 50000 cfm.
Smc manufactures coil line ductwork in 4 5 6 lengths.
Once all the rooms are considered for duct size calculations increase the duct size accordingly.
Now find the total duct losses for each duct and branch that s very easy to do simply multiply the duct length by the pressure drop per meter in our example we found it to be 0 65pa m.
Sheet metal connectors inc.
A common duct pressure of 0 25 inches water column is equal to 0 25 divided by 27 7 in wc psi 0 009 psi.
Adding up all the lengths and effective lengths.
Design cfm 4 cfm 6 cfm 8 cfm 10 cfm 12 60 6x4 60 4x6 90 4x8 120 4x10 150 4x12 90 8x4 110 6x6 160 6x8 215 6x10 270 6x12 120 10x4 160 8x6 230 8x8 310 8x10 400 8x12 150 12x4 215 10x6 310 10x8 430 10x10 550 10x12 180 14x4 270 12x6 400 12x8 550 12x10 680 12x12 210 16x4 320 14x6 490 14x8 670 14x10 800 14x12 240 18x4 375 16x6 580 16x8 800 16x10 950 16x12 270 20x4 430 18x6 670 18x8 930 18x10 1100.